Volume 13, Issue 1 (4-2024)                   2024, 13(1): 7-20 | Back to browse issues page

XML Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Atrkar rowshan D, masoomi F, Toghrolian A, moghassem hamidi F. Lateral cephalometric comparison of dental, skeletal, and soft tissue effects of Twin Block and Guilan Functional Appliance on Class II patients with mandibular deficiency. Journal title 2024; 13 (1) :7-20
URL: http://3dj.gums.ac.ir/article-1-593-en.html
1- Assisant professor, Department of orthodontics, School of dentistry, Guilan university of medical sciences, Rasht,Iran
2- Postgraduate Student of Orthodontics, Student Research Committee, Guilan University of Medical Sciences, Guilan, Iran.
3- Assistant professor, Department of Orthodontics, Qazvin University of Medical Sciences, Qazvin, Iran. , foroughhamidi17@gmail.com
Abstract:   (69 Views)

Introduction:  Class II malocclusion is a common orthodontic discrepancy affecting one-third of the world’s population. Thus, functional appliances that cause forward posturing of the mandible can induce mandibular growth, and are therefore a popular approach for treatment of Class II malocclusion during the growth spurt period.
 This study aimed to compare the dental, skeletal, and soft tissue effects of the Twin Block (TB) and Guilan Functional Appliance (GFA) on Class II patients with mandibular deficiency.
Materials and Method: This retrospective study compared 30 patients treated with TB and 30 patients treated with GFA. All patients had ANB > 5 degrees, SNB < 77 degrees, and overjet > 5 mm. Preoperative lateral cephalograms of patients were compared with their lateral cephalograms obtained after completion of phase II of treatment. Comparisons were made by paired t-test (alpha=0.05).
Results: In the GFA group, SNA significantly decreased from 84.66 to 82.16 degrees (P<0.05) while SNB experienced an insignificant reduction from 75.83 to 74.63 degrees, and ANB experienced a significant reduction from 6.26 to 4.86 degrees (P=0.005). In the TB group, SNA significantly decreased from 82.26 to 81.96 (P<0.05) while SNB increased from 75.43 to 76.69 degrees (P=0.599), and ANB decreased from 6.3 to 5.67 degrees (P=0.049). both the TB and GFA decreased the Wits. This reduction was greater in the GFA group; however, the difference between the two groups did not reach statistical significance(P=0.931).
Conclusion: Despite different designs, both functional appliances were successful in treatment of patients with mandibular deficiency.

Full-Text [PDF 762 kb]   (42 Downloads)    
Type of Study: Original article | Subject: So on
Received: 2024/01/13 | Accepted: 2024/05/21 | Published: 2024/04/22

Add your comments about this article : Your username or Email:
CAPTCHA

Send email to the article author


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

© 2024 CC BY-NC 4.0 | Journal of Dentomaxillofacial

Designed & Developed by : Yektaweb