Volume 8, Issue 3 (7-2019)                   2019, 8(3): 7-14 | Back to browse issues page


XML Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Masaeli R, Ketabat F, Zandsalimi K. Research Paper: Microhardness and Wear Resistance of Glass Ionomer Cements Modified by Chitosan and Nano-Hydroxyapatite. Journal title 2019; 8 (3) :7-14
URL: http://3dj.gums.ac.ir/article-1-475-en.html
1- Department of Dental Biomaterials, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran
2- Department of Surgery, Division of Head and Neck Surgery, School of Medicine, University of Saskatchewan, Saskatoon, Canada
3- Department of Life Sciences Engineering, School of New Sciences and Technologies, University of Tehran, Tehran, Iran
Abstract:   (644 Views)
Abstract
Introduction: Despite the merits of glass ionomer cements (GICs), they suffer from weak mechanical properties such as low wear resistance. In this study, the mechanical properties of GICs after incorporating chitosan and nano-hydroxyapatite was investigated.
Materials and Methods:The samples were prepared in four groups, including non-modified GIGs (NMGIC, n = 5), chitosan incorporated GICs (CHGIC, n = 5), nano-hydroxyapatite incorporated GICs (nanoHAGIC, n = 5), and chitosan/nanohydroxyapatite incorporated GICs (CH/nanoHA/GICs, n = 5). Long-term Vickers microhardness (VH) and wear rate of the samples after immersion in artificial saliva were measured.
Results: The results were analysed using one-way ANOVA followed by Scheffé's test (P < 0.05). Moreover, the microstructure of the samples was investigated via scanning electron microscopy. After 1 hour, the VH values of CH/nanoHA/GICs and CH/GICs were greater than nanoHA/GICs and non-modified GICs (p<0.001). However, there were no statistical differences among VH values of all groups after 11 weeks (p>0.05). Based on the wear tests, adding nanoHA or CH to GICs increased their wear rates, while introducing both of them decreased weight loss of GICs.
Conclusion:Within the limitations of the present study, introducing both nanoHA and CH to GIC enhances GIC’s microhardness and wear resistance. Consequently, the addition of nanoHA and CH is a promising approach for improving mechanical properties of GICs.
 
Full-Text [PDF 865 kb]   (370 Downloads)    
Type of Study: Original article | Subject: General
Received: 2019/07/4 | Accepted: 2019/07/14 | Published: 2019/07/14