جلد 11، شماره 1 - ( 11-1400 )                   جلد 11 شماره 1 صفحات 32-24 | برگشت به فهرست نسخه ها

XML Print


چکیده:   (669 مشاهده)
Introduction: To evaluate and compare shear bond strength of self-cure and 
light-cure composites using a universal bonding system.
Materials and Methods: Superficial coronal dentin of 62 intact extracted 
premolars was exposed and bonding agent (All-Bond Universal) was applied over the 
dentin surface according to the manufacturer instruction (self-etch mode). Then 
samples were distributed in 2 groups (n=31), and composite cylinders were built using AELITE All-purpose Body Light-cure composite (group I) and MasterDent Self-cure composite (group II). Samples were kept in distilled water at room temperature for one week and then were thermocycled (500 cycles, 5 º C to 55º C). Finally, samples were mounted in acrylic molds and shear bond strength was assessed using a Universal Testing Machine  at the crosshead speed of 0.5 millimeter per minute. Stereomicroscope was used to determine the failure mode. Bond strength data were analyzed using sample t-test and frequencies of failure types analyzed using Chi-square test.
Results: Mean shear bond strength in group I (34 ± 3.56Mpa) was higher than group II (32±3.24Mpa). In addition, the prevalence of adhesive failure in group II (74.2%) was higher than group I (67.7%). However, these differences were not statistically significant.
Conclusion: Our findings showed that the application of All-Bond Universal 
followed by a self-cured composite without using a separate self-cure activator on 
dentin, provides bond strength values comparable to that of a light-cured composite.
 
متن کامل [PDF 590 kb]   (400 دریافت)    
نوع مطالعه: پژوهشي | موضوع مقاله: عمومى
دریافت: 1400/12/10 | پذیرش: 1400/12/24 | انتشار: 1401/1/4

بازنشر اطلاعات
Creative Commons License این مقاله تحت شرایط Creative Commons Attribution-NonCommercial 4.0 International License قابل بازنشر است.