Introdouction: The mapping of ghost images of the maxilla and the nasal cavity, which are complex structures, is very important. The position of objects that create a ghost image can differ when using various devices. The purpose of this investigation was to study the mapping of ghost images of the maxilla and the nasal cavity using a Cranex D digital panoramic machine.
Materials and methods: The mapping of ghost images of the maxilla and the nasal cavity, which are complex structures, is very important. The position of objects that create a ghost image can differ when using various devices. The purpose of this investigation was to study the mapping of ghost images of the maxilla and the nasal cavity using a Cranex D digital panoramic machine.
Results: When the lead ball was located in the posterior third of the septum in the anterior-posterior direction and in the middle third above the base of the septum, a ghost image was detected in panoramic view. If the ball was placed in the posterior nasal spine, the image of the object appeared extremely elongated in a horizontal direction. The same was seen when the ball was located in the posterior third of the septum in the anterior- posterior direction and near the base of the septum.
Conclusion: This in vitro study examining ghost image mapping of the maxilla and the nasal cavity, using a Cranex D machine, revealed that the ghost envelope was limited. Digital panoramic device manufacturers have attempted to reduce ghost images, and this has now been achieved with this particular digital machine.

متن کامل [PDF 1254 kb]   (1756 دریافت)    
نوع مطالعه: پژوهشي | موضوع مقاله: تخصصي
دریافت: 1394/2/31 | پذیرش: 1394/2/31 | انتشار: 1394/2/31

ارسال نظر درباره این مقاله : نام کاربری یا پست الکترونیک شما:
CAPTCHA

بازنشر اطلاعات
Creative Commons License این مقاله تحت شرایط Creative Commons Attribution-NonCommercial 4.0 International License قابل بازنشر است.

کلیه حقوق این وب سایت متعلق به مجله دانشکده دندانپزشکی دانشگاه علوم پزشکی گیلان می باشد.

طراحی و برنامه نویسی : یکتاوب افزار شرق

© 2024 CC BY-NC 4.0 | Journal of Dentomaxillofacial

Designed & Developed by : Yektaweb