3dj 2016, 5(4): 17-22 Back to browse issues page
Comparison of Working Length Determination Using Apex Locator and Conventional Radiography in Curved Canals-an In Vitro Study
Elnaz Mousavi, Maryam Mohajer Saem , Zahra Atrkar Roshan, Zahra Pourhabibi
Dental Student Guilan University of Medical Sciences-International Branch, Research Committee Member
Abstract:   (577 Views)

Introduction: The exact measurement of the root canal length is of great importance in root canal therapy. Although, determination of the root canal length through radiography is the most common method, recently electronic apex locators are being used to determine working length and decrease the number of radiographs. The purpose of this study was to compare the accuracy of an electronic apex locator (Root ZX) with conventional radiography to determine the working length of curved mandibular molars.

Materials and methods: 35 intact mandibular first molars with rote curve above 10° were selected. The access cavity was prepared and the root canal length was measured using apex locator (Root ZX) and conventional radiography. Data was analyzed by using the paired-sample t-test.(P<0.05)

Results: The working lengths measured by apex locater were equal to the actual working lengths in 42.86%, 0.5-1 mm shorter in 31.43%, and 0.5 mm longer in 25.71%. The working lengths measured by radiography were equal to the actual working length in 51.14%, 0.5-1mm shorter in 39.99% and 0.5mm longer in 2.86%. There was no significant difference between these two methods in the measurement of the working length (p=0.951).

Conclusion:  The apex Locator and conventional radiography were equally effective in determining of the working length of the curved canals.

Keywords: Radiography, Curved Canal Therapy, Molar First
Full-Text [PDF 462 kb]   (158 Downloads) |   |   Full-Text (HTML)  (191 Views)  
Type of Study: Original article | Subject: Radiology
Received: 2017/02/21 | Accepted: 2017/02/21 | Published: 2017/02/21
Add your comments about this article
Your username or email:

Write the security code in the box >



DOI: 10.18869/acadpub.3dj.5.4.17
PMID:


XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Mousavi E, Mohajer Saem M, Atrkar Roshan Z, Pourhabibi Z. Comparison of Working Length Determination Using Apex Locator and Conventional Radiography in Curved Canals-an In Vitro Study. 3dj. 2016; 5 (4) :17-22
URL: http://3dj.gums.ac.ir/article-1-249-en.html
Volume 5, Number 4 (12-2016) Back to browse issues page
مجله دانشکده دندانپزشکی دانشگاه علوم پزشکی گیلان Journal of Dentomaxillofacial
Persian site map - English site map - Created in 0.136 seconds with 822 queries by yektaweb 3501